S'abonner

L’utilisation du cathéter Heartrail II « 5-in-6 » dans l’angioplastie coronaire complexe : expérience multicentrique - 20/11/13

Doi : 10.1016/j.ancard.2013.09.004 
Y. Derraz a, , H. Benamer a, b, T. Lefèvre b, B. Chevalier b, T. Hovasse b, R. Chaito b, P. Garot b, c, M.-C. Morice b, Y. Louvard a, b
a Hôpital européen La Roseraie, Paris, France 
b Hôpital privé de Jacques-Cartier, Massy, France 
c Hôpital privé Claude-Galien, Quincy, France 

Auteur correspondant. 16, cité des Irlandais, porte 12, 94110 Arcueil, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 3
Vidéos 0
Autres 0

Résumé

Contexte

L’angioplastie des coronaires calcifiées et/ou tortueuses est considérée comme une procédure complexe. Pour surmonter les difficultés techniques plusieurs matériels et stratégies ont été proposés. La technique de « mother and child » utilisant le système « 5-in-6 » a récemment émergé comme un outil efficace pour améliorer le support pendant les interventions coronaires percutanées.

Objectifs

L’objectif de cette étude est de rapporter notre expérience concernant l’utilisation du cathéter Heartrail II « 5-in-6 », dans les angioplasties coronaires complexes et d’évaluer son efficacité et sa sécurité d’emploi.

Sujets et méthodes

Il s’agit d’une étude rétrospective et descriptive sur des procédures utilisant le système « 5-in-6 » chez des patients admis dans trois centres hospitaliers durant la période de juillet 2009 à septembre 2012. C’est le cardiologue interventionnel qui estimait s’il s’agissait d’une bonne indication de l’utilisation du système « 5-in-6 » pour l’angioplastie coronaire.

Résultats

Cent quarante-sept patients ont été inclus dans notre étude. Une majorité masculine : 113 hommes (soit 78 %). L’âge moyen de la population était de 68,5±21,5ans. Cent vingt-huit patient (87 %) ont eu un abord radial, dont 123 par abord radial droit. L’angioplastie a intéressé la coronaire droite dans 82 cas (52 %), l’interventriculaire antérieure dans 35 cas (22 %), la circonflexe dans 18 cas (11,5 %), une artère marginale dans 16 cas (9 %), l’interventriculaire postérieure chez trois patients (0,01 %), la rétroventriculaire chez un patient et un greffon saphène chez deux patients (0,01 %). Les lésions étaient de type (B2 ou C) dans 70 % des cas, avec 50 % de lésions distales, modérément à sévèrement calcifiées dans 62 % des cas, et faisant 16±4mm de longueur moyenne. Il y avait 22 (14 %) procédures de désobstruction chronique dont 18 cas (81 %) ont été traitées avec succès. Le système « 5-in-6 » a été mis avec succès et nous a permis de réussir l’angioplastie chez 139 patients (94 %).

Conclusion

Notre travail confirme la faisabilité et la sécurité d’utilisation du dispositif Heartrail II « 5-in-6 » en cas d’angioplastie complexe.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

The mother and child “5-in-6” technique using the Heartrail II catheter is a novel tool allowing stent delivery in challenging lesions, when conventional techniques have failed.

Methods

A total of 147 consecutive patients underwent percutaneous coronary intervention (PCI) using the “5-in-6” Heartrail II catheter was restrospectively identified in the Institut Cardiovasculaire Paris Sud, (Jacques-cartier hospital), Institut hospitalier Claude-Galien (Claude-Galien hospital) and European hospital of Paris between July 2009 and September 2012.

Results

Ten interventional cardiologists treated 147 patients with the new device. The patients mean age was 68.5±21.5 years, 78% were men. Radial access was used in 128 cases (87.9%). The treated vessels were the right coronary artery in 82%, left anterior descending in 22%, left circumflex in 18%, marginal branch in 9%, the posterior descending artery in three patients, retroventricular artery in one patient and a saphenous graft in two patients. Most lesions (70%) had American Heart Association/American College of Cardiology (AHA/ACC) type B2 or C, and greater than 50% were located in distal vessel segments. Mean lesion length was 16±4mm, which is indicative of long lesion. Most (62%) lesions were moderately to heavily calcified and 22 (14%) were chronic total occlusions. Problems with stent delivery were due to poor guide catheter support or excessive calcification. Introduction of the “Heartrail II” catheter allowed successful stent delivery in 139 cases (94%).

Conclusion

The “5 in 6” Heartrail II catheter is a simple and easy-to-use device that can improve the success of stent delivery in challenging coronary interventions.

Le texte complet de cet article est disponible en PDF.

Mots clés : Angioplastie coronaire, Technique « mother and child », Cathéter « Heartrail II », Occlusion coronaire chronique, Stent

Keywords : Percutaneous coronary intervention, “Mother and child” technique, “Heartrail II” Catheter, Chronic total occlusion, Stent


Plan


© 2013  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 62 - N° 6

P. 392-397 - décembre 2013 Retour au numéro
Article précédent Article précédent
  • La dénervation rénale un traitement pour l’hypertension artérielle résistante : expérience française
  • H. Benamer, D. Mylotte, C. Garcia-Alonso, T. Unterseeh, P. Garot, Y. Louvard, T. Lefevre, M.-C. Morice, ICV-GVM la Roseraie a b c
| Article suivant Article suivant
  • Infarctus du myocarde au cours d’une activité sportive. Caractéristiques cliniques et angiographiques en phase aiguë d’une série de 16 cas
  • X. Halna du Fretay, H. Akoudad, M. Nejjari, H. Benamer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.